  Datasheet File OCR Text:
 OBSOLETE PRODUCT
RoHS Compliant 18-36 V & 33 - 75V Input Range High Efficiency: 87% Typical at 5V 100 S Transient Response 50100% Load Step 420 kHz Fixed-Frequency Operation Remote Sense
VKA60xSC
60 Watt t Br k Contact Factory forWatt Single Output Half Brick DC/DC Converter Replacement Model rick
Operation to +100 C Baseplate Temperature Primary Remote On/Off, Choice of Pos/Neg Logic Adjustable Output Voltage Continuout Short-Circuit Protection Thermal Shutdown Case Ground Pin
The VKA60xSC Series DC/DC converters present an economical and practical solution for distributed power system architectures which require high power density and efficiency while maintaining system modularity and upgradeability. With the ability to operate over a wide input voltage range of 18 to 36 and 33 to 75 volts, these modules are ideal for use in battery
backup applications common in todays' telecommunication and electronic data processing applications. The output is fully isolated from the input, allowing for a variety of polarity and grounding configurations. The VKA60xSC's proprietary control circuitry responds to 50-100% load steps in 100 Seconds to within 1% nominal Vout.
The patented fixed frequency architecture combined with surface mount technology results in a compact, efficient and reliable solution to DC/ DC conversion requirements. Safety per UL1950, EN 60950 and CSA 22.2 #234.
PRODUCT SELECTION CHART
MODEL VKA60LS03C VKA60LS05C VKA60LS12C VKA60LS15C VKA60LS24C VKA60MS03C VKA60MS05C VKA60MS12C VKA60MS15C VKA60MS24C INPUT VOLTAGE 24VDC (18-36) VOUT (VDC) 3.3V 5.0V 12.0V 15.0V 24.0V 3.3V 5.0V 12.0V 15.0V 24.0V IOUT (A) 12.0 12.0 5.0 4.0 2.5 12.0 12.0 5.0 4.0 2.5 EFFICIENCY MIN 80 85 87 88 89 81 86 88 89 89 TYP 81 86 88 89 90 82 87 89 90 90
48VDC (33-75)
THROUGH-HOLE SOLDERING INFORMATION
These devices are intended for wave soldering or manual soldering. They are not intended to be subject to surface mount processes under any circumstances. The normal wave soldering process can be used with these devices where the device is subjected to a maximum wave temperature of 260C for a period of no more than 10 seconds. Within this time and temperature range, the integrity of the device's plastic body will not be compromised and internal temperatures within the converter will not exceed 175C. Care should be taken to control manual soldering limits identical to that of wave soldering.
For full details go to www.murata-ps.com/rohs
www.murata-ps.com
Technical enquiries - email: sales@murata-ps.com, tel: +1 508 339 3000
VKA60xSC.B01 Page 1 of 4
VKA60xSC
SPECIFICATIONS, ALL MODELS
PARAMETER
INPUT Voltage Range VKA60LS VKA60MS Maximum Input Current VKA60LS VKA60MS Reflected Ripple Current Input Ripple Rejection No Load Input Current LS/MS
60 Watt Single Output Half Brick DC/DC Converter
MIN TYP MAX UNITS
Specifications are at TCASE = +40C nominal input voltage unless otherwise specified.
CONDITIONS
18 33 VIN = 16VDC VIN = 27VDC Peak - Peak DC to 1KHz
24 48
36 75 4.4 2.6
VDC VDC A A mA dB mA W W
INPUT
50
20 60 50/100 3.6/4.8 0.18/0.4 0.520 0.360
Power Dissipation LS/MS No Load Standby, Primary On/Off Disabled LS/MS Inrush Charge VIN = VINmax. VKA60LS VKA60MS Quiescent Operating Current Primary On/Off PARAMETER Disabled CONDITIONS OUTPUT Rated Power Set point Accuracy Line Regulation High Line to Low Line Load Regulation No Load to Rated Load Output Temperature Drift Output Ripple, p-p DC to 20MHz BW Output Current Limit Inception Output Short-Circuit Current (2) test Output Overvoltage Limit Transient Response 50 to 100% Load Step Peak Deviation di/dt = 1.0A/ Sec Settling Time VOUT, 1% of Nominal Output
mC mC mA UNITS W % % % %/C VOUT, Nom lOUT, Nom lOUT, Nom V VOUT, Nom Sec
MIN
0
8 TYP
12 MAX 60 1 0.05 0.5
0.02 0.2 .02 1% 130% 120% 125% 2% 100
OUTPUT
150% 150% 135%
PARAMETER
ISOLATION Input to Output Input to Baseplate Output to Baseplate Resistance Capacitance Leakage Current GENERAL Efficiency, Line, Load, Temp. (3) Switching Frequency Remote Sense Compensation Output Voltage Adjust Range Remote On/Off Control Inputs Primary Sink Current-Logic Low Vlow Vhigh Turn-on Time Weight TEMPERATURE Operation/Specification Storage Shutdown Temperature Thermal Impedance, case-ambient Lead Solder Temperature
CONDITIONS
Peak Test for 2 Seconds
MIN
1500 1500 500 10
TYP
MAX
UNITS
VDC VDC VDC M pF A, rms
VISO = 240VAC, 60Hz
2000 180
GENERAL
400 12V & higher(4) Open Collector/Drain
420 -50% / +25%
440 0.5
KHz V VOUT, Nom
Within 1% of Rated Output
10.0
1.0 0.4 Open Collector 12.5 85 (3.0) +100 +125 +115 +300
mA V mSec g (oz.) C C C C/W C
Case Temperature Case Temperature Case Temperature 10 Seconds max
-40 -55 +100
+25 +25 7.1
NOTES: (1) See Typical Performance Curves, page 3 (2) Continuous Mode (3) See graphs for Efficiency vs. Output Load, VIN, TCASE (4) 3.3V Models Limited in Trim Down Range (5) Consult Factory for Details
www.murata-ps.com
Technical enquiries - email: sales@murata-ps.com, tel: +1 508 339 3000
VKA60xSC.B01 Page 2 of 4
VKA60xSC
60 Watt Single Output Half Brick DC/DC Converter
TCASE = +40C nominal input voltage unless otherwise specified.
TYPICAL PERFORMANCE CURVES
VKA60 xSzz Device Family Indicates 50 Watt Regulated Unit Model Number Selected from Table of Electrical Characteristics Where: x = Input Voltage (L = 24VDC; M = 48VDC) zz = Output Voltage (03=3.3V, 05=5V, etc.) Lead Length 0.200" - No Number 0.145" - (6) 0.110" - (8) Remote On-Off Logic: Positive - No Number Negative - (1) RoHS Compliant
C
www.murata-ps.com
ORDERING INFORMATION
Technical enquiries - email: sales@murata-ps.com, tel: +1 508 339 3000
VKA60xSC.B01 Page 3 of 4
VKA60xSC
60 Watt Single Output Half Brick DC/DC Converter
MECHANICAL
NOTES: All dimensions are in inches (millimeters).
0.530 MAX [13.46] 0.20 [5.1]
PIN PLACEMENT TOLERANCE: 0.005" MECHANICAL TOLERANCE: 0.015"
.040 [1.02] DIA. 7 PLACES .081 [2.06] DIA. 2 PLACES
Marked with: specific modeL ordered, date code, job code. MATERIAL: Units are encapsulated in a low thermal resistance molding compound which has excellent chemical resistance and electrical properties in high humidity environments and over a wide operating temperature range. The encapsulant and outer shell of the unit have UL94V-0 ratings. Lead material is solder plated to allow ease of solderability.
0.20 [5.1] 0.50 [12.7]
0.40 [10.16]
.400 [10.16]
2.000 [50.80] 1.000 [25.40] 2.40 [61.0] MAX
VKA60xSC
0.700 [17.78]
1.000 [25.40] 1.400 [35.56]
1.400 [35.56]
0.19 [4.8]
1.900 [48.26]
MOUNTING INSERTS M3 X 0.5 THRU, 4 PLACES MAX. TORQUE, 8 IN/LBS
2.28 [57.91] MAX
OUTPUT ADJUST VOLTAGE
This feature allows the user to accurately adjust the module's output voltage set point to a specified level. This is achieved by connecting a resistor or potentiometer from the TRIM terminal to either the +Vout terminal (for increased Vout) or the -Vout terminal (for decreased Vout). The formulae below describe the trim resistor value to obtain a Vout change of %. VO is output voltage prior to adjustment (3.3V, 5V, 12V, 15V, or 24V). Radj - up =
OVP NOTE
Special attention should be given to the peak voltage deviation during a dynamic load step when trimming the output above the original set point to avoid tripping the overvoltage protection circuit. Should an OVP condition occur, the converter will go into a latch condition and must be externally reset before it will return to normal operation.
(
Vo(100 + %) 1.225 %
_
(100 + 2 %) %
)
Radj - down =
(100
- 2) %
USA: UK: France: Japan: Tucson (Az), Tel: (800) 547 2537, email: sales@murata-ps.com Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com Website: www.murata-ps.jp Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com Canada: Toronto, Tel: (866) 740 1232, email: toronto@murata-ps.com
Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
www.murata-ps.com email: sales@murata-ps.com ISO 9001 REGISTERED
07/28/08
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. (c) 2008 Murata Power Solutions, Inc.
Germany: Munchen, Tel: +49 (0)89-544334-0, email: munich@murata-ps.com
China:
www.murata-ps.com
Technical enquiries - email: sales@murata-ps.com, tel: +1 508 339 3000
VKA60xSC.B01 Page 4 of 4


▲Up To Search▲   

 
Price & Availability of VKA60LS03C

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X